Factory Customized Protective 3-Phase Induction Motor Reverse Preventive Relay Voltage Relay
We emphasize advancement and introduce new products and solutions into the market each year for Factory Customized Protective 3-Phase Induction Motor Reverse Preventive Relay Voltage Relay, Since the manufacturing unit founded, we have committed on the advancement of new goods. Together with the social and economic pace, we’ll continue to carry ahead the spirit of “high top quality, efficiency, innovation, integrity”, and stay with the operating principle of “credit initial, customer 1st, excellent excellent”. We are going to create a amazing foreseeable future in hair generation with our partners.
We emphasize advancement and introduce new products and solutions into the market each year for Protective Relay and Motor Reverse Relay, Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to supply our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We have been ready to face the worries and make the improve to understand all the possibilities in international trade.
|
Contact Arrangement |
1Z 、1H |
2Z 、2H、 |
3Z 、3H 、4Z 、4H |
|
|
Contact Resistance |
≤ 100mΩ(1A 6VDC) |
|||
|
Contact Material |
SiIver AIIoy |
|||
|
Contact Rating(Resistive) |
15A/240VAC 15A/30VDC |
|
10A/240VAC 10A/30VDC |
|
|
Max. Switching Voltage |
240VAC/30VDC |
|||
|
Max. Switching Current |
15A |
|
10A |
|
|
Max. Switching Power |
3600VA/450W |
|
2400VAC/300W |
|
|
Mechanical Life |
2×107operations |
|||
|
Electrical Life |
1×105operations |
|||
|
Insulation Resistance |
100MΩ (at 500VDC) |
|
|
Dielectric Strength |
Between coil & contacts |
2000VAC 1min |
|
|
Between open contacts |
1500VAC 1min |
|
|
Between contacts sets |
2000VAC 1min |
|
Operate time (at nomi. volt.) |
≤25ms |
|
|
Release time (at nomi. volt.) |
≤25ms |
|
|
Humidity |
35% ~ 85% RH |
|
|
Storage Condition |
-40°C~+85°C |
|
|
Operating Condition |
-40°C~+70°C |
|
|
UL Class B/F |
Insulation System Class B/F |
|
|
Shock Resistance |
Functional |
98m/s2 |
|
|
Destructive |
980m/s2 |
|
Vibration resistance |
10Hz ~ 55Hz 1mm DA |
|
|
Unit weight |
1C:37g 2C:50g 4C:65g |
|
|
Construction |
Dust Cover Type |
|
Notes:1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curved below.
|
Nominal VDC |
Pick-up Voltage (Max.) VDC |
Drop-out Voltage (Min.) VDC |
*Max. Allowable VDC |
Coil Resistance Ω± 10% |
|
5 |
4 |
0.5 |
5.5 |
27.5 |
|
6 |
4.5 |
0.6 |
6.6 |
40 |
|
12 |
9.0 |
1.2 |
13.2 |
160 |
|
24 |
18.0 |
2.4 |
26.4 |
630 |
|
48 |
36.0 |
4.8 |
52.8 |
2560 |
|
1 10 |
82.5 |
1 1.0 |
121.0 |
13500 |
|
220 |
176 |
22.0 |
242.0 |
30000 |
Note: “*Max Allowable Voltage” : The relay coil can endure max allowable voltage for a short period time only.
|
Nominal VAC |
Pick-up Voltage (Max.) VAC |
Drop-out Voltage (Min.) VAC |
*Max. Allowable VAC |
Coil Resistance Ω± 10% |
|
6 |
4.8 |
1.8 |
6.6 |
12 |
|
12 |
9.6 |
3.6 |
13.2 |
45 |
|
24 |
19.2 |
7.2 |
26.4 |
180 |
|
48 |
38.4 |
14.4 |
52.8 |
750 |
|
120 |
96.0 |
36.0 |
132.0 |
4300 |
|
220 |
176.0 |
66.0 |
242.0 |
16000 |
|
250 |
200.0 |
75.0 |
275.0 |
18000 |
|
380 |
304.0 |
1 14 |
418.0 |
32000 |
Note: “*Max Allowable Voltage” : The relay coil can endure max allowable voltage
for a short period time only.

| Coil Power | DC:900mW |
| AC: 1.2VA |
|
CQC
|
10A 250VAC AC- 12 10A 24VDC DC-12 |
NOTES:
1. All values without specified temperature at 25°C.
2. The above only lists the typical loads. Other loads may be available upon request.


This datasheet is for customers‘ reference. All the specifications are subject to change without notice.We emphasize advancement and introduce new products and solutions into the market each year for Factory Customized Protective 3-Phase Induction Motor Reverse Preventive Relay Voltage Relay, Since the manufacturing unit founded, we have committed on the advancement of new goods. Together with the social and economic pace, we’ll continue to carry ahead the spirit of “high top quality, efficiency, innovation, integrity”, and stay with the operating principle of “credit initial, customer 1st, excellent excellent”. We are going to create a amazing foreseeable future in hair generation with our partners.
Factory Customized Protective Relay and Motor Reverse Relay, Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to supply our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We have been ready to face the worries and make the improve to understand all the possibilities in international trade.